Gallery
Reaction of aluminum sliding door glazing during the fire resistance test
Test of the functional resistance of cable systems
Cable systems specimen after the completion of the functional resistance test
Fire door specimen with integrated ventilation grille during the fire resistance test according to EN 1634-1
Inside view of the test furnace during the fire resistance test according to EN 1364-2
Glazed wall in the test furnace with the dimensions of 5 × 5 m
View of the exposed side of a test specimen after the fire resistance test
Skylight activation during the heat resistance test
Heat resistance test of a skylight (smoke and heat exhaust ventilator)
View of the exposed side of a door wing during the fire resistance test
Test of a roof assembly exposed to external fire conditions – BROOF(t1) rating according to CEN/TS 1187 (classification according to EN 13 501-5)
Test of a roof assembly with PVC waterproofing membrane exposed to external fire conditions – BROOF(t1) rating according to CEN/TS 1187 (classification according to EN 13 501-5)
Aluminum panel during the test according to EN 13 823 (SBI – Single Burning Item)
Linear insulation during the test according to EN 13 823 (SBI – Single Burning Item)
Test of PES composite and glass fiber support grating according to EN 13 823 (SBI – Single Burning Item)
3D PVC wall covering during the test according to EN 13 823 (SBI – Single Burning Item)
PIR foam during the test according to EN ISO 11925-2 (small flame)
Test device according to EN ISO 11925-2 (small flame)
EN 12101-2, Annex E (loading under low ambient temperature)
EN 12604+A1 (resistance to cyclic opening and closing)
EN 12101-2, Annex C (reliability)
EN 12101-2, Annex D (opening under load)
EN 1191 (resistance to cyclic opening and closing)
EN 12101-2, Annex D (opening under load)
EN 12101-2, Annex G (heat resistance test)
EN 12444 (wind load resistance)
Test chamber for physical tests according to EN 1873 in the horizontal position
EN 1873 (watertightness)
EN 1873 (resistance to the impact of a large soft body)
EN 12101-2, Annex F (wind load)
EN 1873 (resistance to the impact of a small hard body)
Model of a product manufactured for aerodynamic performance testing according to 12101-2
Device for testing the aerodynamic free area of heat and smoke exhaust ventilators according to EN 12101-2
Model of a test specimen produced for aerodynamic performance testing according to 12101-2
Model of a test specimen produced for aerodynamic performance testing according to 12101-2
Model of a test specimen produced for aerodynamic performance testing according to 12101-2
Device for testing the aerodynamic free area of heat and smoke exhaust ventilators according to EN 12101-2
Smoke tightness testing chamber
Fire resistance testing chamber, horizontal
Fire resistance testing chamber, vertical
Single Burning Item (SBI) device, reaction to fire testing
Any further questions?
We’re here to help!